你懂的视频在线一区二区-精品国产亚洲午夜精品a-成人av高清正版在线观看-亚洲欧洲美色一区二区三区

Welcome to Tianjin Guoce Aerospace Technology Co., Ltd!

Tianjin GuoCe Aerospace Technology Co., Ltd.

Inspection Industry Solution Provider

We are more professional.

Testequipment

Telephone:18322499311

Mobile phone:18920407795

Fax:022-22145487

E-mail:10533646999@qq.com

Address:Chagugang Town, Wuqing District, Tianjin

Salt spray testing machine

  • Hot Line:18322499311
Highlight-color: rgba(255, 255, 255, 0); margin: 0px; color: rgb(102, 102, 102); font-family: 宋體; font-size: 14px; width: 700px; overflow: hidden; padding: 0px;">


Salt spray testing machine

1、 Product Description:


Main functions of the device:


The salt water spray tester is used to test the corrosion resistance of the products after the surface of various materials has undergone corrosion treatment such as electroplating, anodizing, spraying, and antirust oil

Performance indicators and system composition of programmable Salt spray testing machine


Model GC-YW-120B

Volume and size

Nominal internal volume 600 L

Effective size of inner box 1200 × 1000 × 500 W × H × D (mm)

The external space is approximately 1860 × 1160 × 1400 W × H × D (mm) as shown in the figure

Weight 250kg

Maximum power 320KW

Maximum current 1*

 

Power supply conditions

And power supply AC 220V single-phase R N+protective grounding; The allowable voltage fluctuation range is 10% V;

The allowable frequency fluctuation range is 50 ± 0.5HZ; TN-S power supply or TT power supply

The grounding resistance of the protective grounding wire is less than 4 Ω

Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must independently control the use of the equipment

performance index 

The values measured under the environmental conditions of+25 ℃, relative humidity ≤ 85%, and no sample in the test chamber.

Temperature and humidity range laboratory temperature: RT~ 50℃

Pressure bucket temperature: RT~ 63℃

Relative humidity ≥ 85% HR

Main technical parameters: Temperature resolution: 0.1 ℃

Temperature deviation: ±1℃                    

Temperature uniformity: 1 ℃

Temperature fluctuation: ± 0.5 ℃

Spray volume (m1/80cm2/h) 1.0~2.0 (collect at least 16 hours and take the average value)

Spray pressure: 1.00 ± 0.01kgf/cm2

PH value: neutral 6.5~7.2 acidic 3.0~3.3

Control time: 1S~9999H can be set arbitrarily

Spray time: 1S~99H can be set arbitrarily

Rest time: 1S~99H can be set arbitrarily

The test meets the standard GB/T 2423.18-2000 Salt Spray Test

GB/T 10125-1997 Salt Spray Test

ASTM.B117-07 Salt Spray Test

JIS H8502 Salt Spray Test

IEC 60068-2-11:1981 Salt spray test

IEC68-2-52 1996 Salt Spray Test

GB/T 12967.3-91CASS Accelerated Acetate Salt Spray Test

GBT 5170-8-2008 Salt Spray Test Equipment

GJB150.11A-2009 Military Equipment Laboratory Environmental Test Methods Salt Spray Test

GB/T2423.17-2008 Salt spray test method

CNS 4159 Test Method of Copper Acetate Salt Water spray for Surface Treatment

CNS 4158 Salt water spray test method for surface treatment

Heating rate laboratory temperature RT →+50 ℃ ≤ 40 min

Pressure bucket temperature RT →+63 ℃ ≤ 35 min

structure characteristics

The box structure laboratory adopts PVC polyethylene board with a thickness of 8mm and a durable temperature of 85 ℃.

The laboratory sealing cover is made of PVC polyethylene board with a thickness of 5mm

The test drug replenishment bottle adopts a hidden water level gauge, which is easy to clean and not easy to break.

The pressure air tank adopts SUS # 304 stainless steel, which has the best insulation effect for high-pressure resistant tanks

The machine base is made of stainless steel welded into a mesh structure

The bottom of the machine is equipped with casters and fixed foot cups for easy movement and positioning

The test material rack adopts a flat indexing rack, which can adjust the angle freely to cover and receive fog on all four sides, and can accommodate a large number of samples

The sealing cover adopts pneumatic type, just click the switch cover button to open and close the sealing cover

The laboratory seal adopts water sealing method to ensure that corrosive gases inside the box do not leak

The control box and test box are integrated, and the left and right structures are easy to operate

The whole machine is a desktop structure with a beautiful appearance

The sealing cover of the box cover laboratory is made of PVC polyethylene board with a thickness of 5mm

Make a top 1100 corner sealing cover

The observation window is made of acrylic sheet

Manual defogging device

Control panel water test indicator, overtemperature indicator, end indicator, spray indicator, demist indicator

Laboratory temperature controller, pressure tank temperature controller, timer, accumulator, programmable timer

Main power switch, operation switch, timing switch, spray switch, demist switch

Distribution control cabinet water filling solenoid valve, spray solenoid valve, demisting solenoid valve, distribution board, cooling fan

Over temperature protector, air saturation pressure tank, spray control valve, single-phase valve, test box switch cover switch

The heating system adopts steam heating method, and the titanium alloy heating tube P.I.D controls the heating to achieve temperature balance

There are two types of water replenishment control systems: manual and fully automatic. Simply connect the tap water pipe to automatically control it, making it easy to use

Note: If there are too many impurities or acidity in tap water, a filter should be installed at the inlet

Drainage system drainage valve control device, manual drainage mode

The spray system adopts Bernoult principle to absorb salt water and then atomize, with uniform atomization degree

No blocking crystallization phenomenon can ensure the standard of continuous testing

The nozzle is made of special glass

Spray mode continuous/intermittent

The spray pressure of the air supply system is adjusted to 1kg/cm2 in two stages. For the first time, the compressed air is adjusted to 2kg/cm2 to enter the saturated barrel for heating, and for the second time, the spray pressure is adjusted to 1kg/cm2

The fully automatic pressure balanced fog removal device of the fog removal system only needs to be connected to the fog removal pipe, and automatically removes fog according to the pressure inside the box

electric control system 

Controller LCD display temperature controller, controls the temperature of the laboratory and pressure tank

Temperature input mode button based input

The temperature display can show the set temperature value and the actual temperature value

Work timer digital display timer, unit: seconds, minutes, minutes, hours, ten hours switchable, maximum timer

9999 hours, minimum timing of 1 second

Timer setting method key input

Program timer digital display program timer, two sets of time can be set arbitrarily, infinite loop, timing units: seconds, minutes, minutes, hours, ten hours can be switched, each set has a maximum timing of 99 hours and a minimum timing of 1 second

Program setting method: key input

Continuous operation mode

The one-time cumulative timer can monitor the total working time of the machine

Temperature setting range, maximum temperature range, upper and lower limits of 5 ℃

The panel displays the set temperature value, the current temperature value, the set time, the current time, the total working time of the machine, the abnormal overtemperature indicator, the abnormal water shortage indicator, the end of operation indicator, the spray status indicator, and the defogging status indicator

Safety protection device

Extreme over temperature protection and water shortage protection for the test chamber

Saturated bucket extreme over temperature protection, water shortage protection

Heating system heating tube dry burning, abnormal water supply, abnormal drainage

Power leakage protection, overload and short circuit protection

Storage environment requirements: The equipment environment temperature should be maintained within 0 ℃ to+25 ℃

The installation site requires that the distance between the left, right, and rear wall panels of the test box and the wall should not be less than 600mm, and the distance between the front and the wall should not be less than 800mm. When transporting equipment, whether it is possible to enter the entrance or passage, elevator, etc., to avoid affecting the progress of your company's project.

Acceptance criteria and third-party verification

1. Acceptance criteria: Technical indicators shall be in accordance with the methods specified in the "Technical Agreement" signed by both parties.

2. Acceptance method: Formal acceptance shall be conducted on the site of the purchaser.

3. If the purchaser needs to invite a third party (verified by the National Environmental testing Equipment Quality Inspection Center and issued a valid inspection report) to participate in the acceptance before leaving the factory, the cost shall be borne by the purchaser. If the first acceptance is not qualified, the cost incurred during the second acceptance after improvement by the supplier shall be borne by the supplier.

4. The customer entrusts the National Environmental Testing Equipment Quality Inspection Center to conduct calibration on their own.

         



Recommended products

国产精品日韩欧美第一页| 亚洲在线观看福利视频| 欧美国产日韩在线综合| 99视频精品免费视频| 欧美极品欧美精品欧美| 中文字幕一区二区三区中文| 久久99爱爱视频视频| 日韩美女偷拍视频久久| 欧美日韩有码一二三区| 国产av熟女一区二区三区蜜桃| 青青操日老女人的穴穴 | 亚洲妇女黄色三级视频| 欧美黄色黑人一区二区| 日韩欧美一区二区黄色| 久久大香蕉一区二区三区| 国产午夜精品亚洲精品国产| 日韩精品少妇人妻一区二区| 99国产高清不卡视频| 亚洲日本韩国一区二区三区| 亚洲国产精品久久综合网| 日本不卡片一区二区三区| 亚洲一区二区三区中文久久| 99少妇偷拍视频在线| 国产伦精品一区二区三区精品视频| 激情图日韩精品中文字幕| 欧美一区二区三区五月婷婷| 久久99午夜福利视频| 日本人妻熟女一区二区三区| 亚洲国产性生活高潮免费视频| 国产精品日韩欧美一区二区 | 日本高清不卡一二三区| 免费性欧美重口味黄色| 日本人妻中出在线观看| 欧美日韩国产精品第五页| 午夜福利网午夜福利网| 情一色一区二区三区四| 欧美国产精品区一区二区三区| 中文精品人妻一区二区| 国产精品一区二区传媒蜜臀| 国产老女人性生活视频| 精品欧美在线观看国产|